Dubai Yellow Pages Online

Friend Experimental Analysis Instrument Co., Ltd | E-Showroom

Home » Products »  Alcohol content analyzer in blood gas chromatograp

Alcohol content analyzer in blood gas chromatograp

Price : USD5300
Ready Stock

Friend



Scope

Determination (drinks) volatile organic compounds, blood alcohol
content detection, detection of indoor air pollutants (TVOC), flavor liquor
composition analysis, transformer oil analysis, testing, high-purity gas
analysis of residual solvents in pharmaceuticals, medical devices remaining in
Determination of ethylene oxide.

Chromatograph units are mainly used: liquor factory, other wineries,
petrochemical, gas liquefaction plant, the coal industry, environmental
testing, inspection station, Forensic Center, the public security system, food
plants, quality inspection departments, water plants, pharmaceutical plants,
detection of pesticide plants, gas plants, chemical plants, packaging plant,
paint factory, honey factory, chemical engineering universities and other trace
ingredients are required to use gas chromatography, liquid chromatography

 

Features

1. Large-screen LCD English display. Easy to learn.

2. With self-diagnosis, over-temperature shutdown protection, file
storage, recall, fifth-order temperature-programmed functions, with
single-column automatic compensation function; to ensure the stability of the
baseline temperature programmed analysis.

3. Instrument has dual packed column inlet capillary column three,
three gas independent way.

4. With six independent temperature control area, after intelligent
door systems, cooling is very fast; each of the gasification chamber, detector
and amplifier are modular design, installation is very easy to replace.

5. Complete with a separate capillary analysis system, an
independent capillary split sampler (includes a diaphragm cleaning, split and
tail blowing conditioning). Optional capillary split / splitless injector.

6. Instrument equipped with a flame ionization detector, thermal
conductivity detector, a flame photometric detector, electron capture detector,
NPD five kinds of detectors, three detectors can be installed, the user can
according to their own self-analysis requires optional , also increase the
six-way injection valve, reformer devices; and to achieve detector series and
parallel work.

 

Technical Parameters

Temperature Indicators

1. Temperature Area: column oven, injector, detector

2. Temperature range: room temperature on 5 ℃ ~ 450 ℃ (Increment 1 ℃)

3. Temperature accuracy: better than ± 0.1 ℃

4. Temperature program: Eight-order rate of 0.1 ℃ ~ 40 ℃ / min (increments of 0.1 ℃)

 

 

 

 

FGC-1010 Series gas chromatograph each detector main technical
indicators

                   




Index detector


Sensitivity


Drift (30min)


Linear




Hydrogen flame FID


Mt <5×10-11g/s(Hexadecane)


<2.5×10-14A


>106




Thermal conductivity TCD


S>3000mv.ml/mg(Hexadecane)


<0.05mv


>104




Electron capture ECD


M1 < 1 ×10-13g/ml(r-666)


<0.05mv


>104




N, P NPD


N:M1<5×10-12g/s(Azobenzene)
P:M1<2×10-12g/s(Malathion)


<1×10-12A


>104




Flame photometric FPD


M1<5×10-11g/s(Thiophene in S)
M1<3×10-11g/s(Methyl parathion in P)


<1×10-13A


>102
>103




 

  • Product Details
  • Brand : Friend
  • Place of Origin : China
  • FOB Price : USD5300
  • Minimum Order Quantity : 1
  • Supply Ability : Ready Stock
  • Packaging & Delivery
  • Packaging Detail : wooden case
  • Delivery Detail : 15 workdays
Scope Determination (drinks) volatile organic compounds, blood alcohol content detection, detection of indoor air pollutants (TVOC), flavor liquor composition analysis, transformer oil analysis, testing, high-purity gas analysis of residual solvents in pharmaceuticals, medical devices remaining in Determination of ethylene oxide.