Welcome to Dubai Yellow Pages Online
Dubai Yellow Pages Online DUBAI YELLOW PAGES ONLINE
Global Site for local Search
Get it on Google Play
PACKLESS Heat Ex changers & Vibration absorbs, eleminators

PACKLESS Heat Ex changers & Vibration absorbs, eleminators

Price : AED 100
Ready Stock

Turbo Heat Exchangers

Packless turbo heat exchangers are specifically intended for application on refrigeration systems to transfer heat between liquid refrigerant leaving the condenser on the high pressure side of the system and refrigerant vapor leaving the evaporator on the low pressure side of the system.

This heat transfer may be desirable for several reasons:

  • To raise the vapor temperature to prevent frosting or condensation on the suction line.
  • To evaporate any remaining liquid in the vapor stream to prevent possible compressor damage.
  • To subcool the liquid to prevent flash gas in the liquid line.
  • To increase system refrigerating capacity

Packless vibration absorbers are designed for installation in the suction and discharge lines of air conditioning and refrigeration system to dampen the transmission of compressor-induced vibration through system piping.

Packless vibration absorbers are constructed of deep pitch corrugated tubing in stainless steel for increased flexibility and vibration absorption, covered with high tensile stainless steel wire braid for superior strength. The vibration absorbers have female copper end connections for making sweat connections to refrigerant piping.

Each absorber is pressure tested then carefully vacuum tested using a highly sensitive helium mass spectrometer leak detection device. Units are cleaned, dehydrated and sealed in plastic film after final inspection to maintain cleanliness and dryness prior to installation. These are available either in bulk or individually boxed.

Packless Vibration Absorbers are compatible with all HFC, HCFC and CFC refrigerants. The stainless steel models, VAFS-3 through VAFS-11, are electrically welded with no braze joints to achieve the higher working pressures set by today’s industry standards.

Packless vibration absorbers are recognized under the component programs of Underwriter’s Laboratories, Inc., c-UL-US, File #SA2575.


Packless model VAF vibration absorbers are designed for installation in the suction and discharge lines of air conditioning and refrigeration systems to dampen the transmission of compressor-induced vibration through system piping.

Packless VAF's are constructed of deep pitch corrugated tubing for increased flexibility and vibration absorption, covered by high tensile wire braid for superior strength. Tubing and braid are reinforced by ferrules at each end, and connected to female copper tube ends by high temperature braze alloys. The units are designed for making sweat connections to refrigerant piping. Eleven models are available to fit copper tubing sizes from 1/4 inch through 1-5/8 inches O.D.

Each VAF is pressure tested then carefully vacuum tested using a highly sensitive helium mass spectrometer leak detection device. Units are cleaned, dehydrated and sealed in plastic film after final inspection to maintain cleanliness and dryness prior to installation. VAF's are available either in bulk or individually boxed.

Packless VAF's are recognized under the component programs of Underwriter's Laboratories, Inc., (C-UL-US) for application on both suction and discharge lines.

  • Product Details
  • Brand :
  • Place of Origin : United States
  • FOB Price : AED 100
  • Minimum Order Quantity : Not Given
  • Supply Ability : Ready Stock
  • Packaging & Delivery
  • Packaging Detail : Not Given
  • Delivery Detail : Not Given





Refrigerant Heat Exchangers

Refrigerant Heat Exchanger

View Products

  • Coaxial design for optimum heat transfer
  • Sizes to fit 1/3 to 50 H.P. capacity systems
  • 1/3 H.P. through 10 H.P. constructed with copper outer tube and red brass inner tube
  • 15 H.P. through 50 H.P. constructed with steel outer tube and stainless steel inner tube
  • C-UL recognized or listed

Turbo Heat Exchangers

Packless turbo heat exchangers are specifically intended for application on refrigeration systems to transfer heat between liquid refrigerant leaving the condenser on the high pressure side of the system and refrigerant vapor leaving the evaporator on the low pressure side of the system.

This heat transfer may be desirable for several reasons:

  • To raise the vapor temperature to prevent frosting or condensation on the suction line.
  • To evaporate any remaining liquid in the vapor stream to prevent possible compressor damage.
  • To subcool the liquid to prevent flash gas in the liquid line.
  • To increase system refrigerating capacity.
heat exchangerPackless utilizes a counterflow "tube-in-tube" design for turbo heat exchangers.

Packless utilizes a counterflow "tube-in-tube" design for turbo heat exchangers. Refrigerant vapor flows through the inner tube in a counterflow direction to the liquid refrigerant flowing in the annulus between the inner and outer tube. This counterflow path provides the greatest temperature difference between the two refrigerant streams to yield optimum heat transfer. To further maximize heat exchanger performance with minimum size, the inner tube is convoluted to impart turbulence to both refrigerant flows while the straight-through design helps maintain low refrigerant pressure drops.

Turbo heat exchangers are available to fit refrigeration systems of 1/3 to 80 H.P. capacities:

  • HXR series - 8 standard sizes for nominal 1/3 to 10 H.P. systems.
  • LHXR series - 9 standard sizes from 15 to 50 H.P. systems.

Each unit is furnished with I.D. sweat connections on both the vapor and liquid sides for ease of installation. Standard sizes are recognized or listed by Underwriter's Laboratories, Inc. (C-UL) for use with the following refrigerants:

R12R22R23R125R134AR401A
R401BR402AR402BR404AR407AR407B
R407CR408AR409AR410AR410BR412A
R502R507R508R509  

Selection Procedures

Typically, refrigerant heat exchanger selection is predominantly dependent on nominal system horsepower. The HXR and LHXR models are designed and rated to provide a nominal 10ºF liquid subcooling and 20ºF suction gas superheat for R-22 and R-502. At this rating point, the system is operating at 110ºF condensing temperature. As an example, select model HXR-250A for a nominal 5 H.P. system.

Caution must be exercised to avoid selecting undersized model. The use of undersized models can cause system operation problems such as gas whistling and high suction side pressure drop. This also may have adverse effect on overall system performance. In some applications, the refrigerant heat exchangers selected are oversized to attain additional liquid subcooling and suction gas superheat. This is an acceptable application as long as the temperature of the return gas to the compressor is less than 65ºF to maintain proper compressor performance.

The selection of refrigerant heat exchanger can be based on matching of the system suction and liquid line sizes with the connection size of the heat exchanger, for standard low, medium, and high temperature refrigeration systems. Selection based on line size comparison also must have the nominal system horsepower rating closely matched with HXR, LHXR model rating.




Packless vibration absorbers are compatible with the following refrigerants:

R12R22R23R125R134AR401A
R401BR402AR402BR404AR407AR407B
R407CR408AR409AR410AR410BR412A
R502R507R508R509